DESCRIPTION Easy to learn, simple to operate and complete, IL’s GEM Premier 4000 with iQM revolutionizes whole blood testing. The GEM Premier 4000 is the most comprehensive whole blood analyzer available today, offering a flexible analyte menu including pH, pO2, pCO2, electrolytes, metabolites and onboard CO-Oximetry. View & download of more than 831 Gemini PDF user manuals, service manuals, operating guides. Music mixer user manuals, operating guides & specifications.
One moment please..
Instrumentation Laboratory - GEM Premier 3500
by Instrumentation Laboratory
DESCRIPTION
The GEM Premier 3000 simplifies every aspect of whole blood testing while delivering fast, reliable results in the lab or at the point of care.Building on the unprecedented testing simplicity, flexibility and reliability of the GEM Premier 3000, the GEM Premier 3500 offers new capabilities in an enhanced system, adaptable to the needs--and volume--of the hospital and lab.With its self-contained cartridge, intuitive touch-screen displays and automated quality control, basic operation can be learned in minutes.Add the GEM OPL CO-Oximeter and the GEM PCL Plus coagulation laboratory to create a comprehensive critical care-testing portfolio.
1990 pontiac formula 350. It was also seen as the performance division of General Motors for many years.Some of Pontiac’s models still remain favourites today, such as the Firebird, which has enjoyed a long production history starting in 1967 up to 2002.
Mini Wireless Keyboard -With Touchpad User’s Manual Ver:08RF/2.2 Safety Precautions Safety Matters To avoid injury,death of personnel or damage to the equipment the operator must refer to the explanations in this User’s Manual. Battery: There is a lithium-ion rechargeable battery in this device.Don’t. Get your user manual by e-mail. Enter your email address to receive the manual of eSYNiC Ver 08RF-2.2 Mini Wireless keyboard-TouchPad in the language / languages: English as an attachment in your email. The manual is 0,82 mb in size. User ’s Manual Ver: 08 RF /2. Safety Precautions Safety Matters To avoid injury,death of personnel or damage to the equipment the operator must refer to the explanations in this User ’s Manual. Battery: There is a lithium-ion rechargeable. This is a wonderful combo , 2.4GHz Mini Wireless QWERTY keyboard,TouchPad combo,with USB. Mini wireless keyboard user manual ver 08rf 2.2.
FORUMSView All (10)
Ask a New Question1Reply3 years ago | 3 years agoprice please let me know the price.of gem premier 3500 regards renato rocha Reply |
-Thta1 4 years ago | 4 years agoCapillary Samples I am having challenges analyzing fetal scalp capillary samples on the GEM 3500. The equipment gives a low sample volume error despite the sample volume exceeding the required sample volume. The capillary tube carries 200 UL while the instrument requires 150UL of sample. Anyone having a similar challenge? What could be the issue. The instrument runs the other samples without any issue. Reply |
0Replies5 years ago | 5 years agoNew CLIA regs How is IL going to approach new CLIA regs with running controls every 8 hrs ACCA Manuals J, S, and D are referenced and required across America. This form provides a quick and easy review the HVAC system design. This review gives an objective indication whether required processes were followed. Manual J Load Calculations: Estimates are correct for the amount of heating and cooling required for a residence. Downloads - Public Files. Back to Library. ACCA Speed-Sheet for Manual S. Manual S 1st Edition (Prior to 2014) Speed-sheet 83K 1 version Uploaded -. Air Conditioning Contractors of America Association, Inc. 2800 Shirlington Rd, Suite 300 Arlington, VA 22206. Manual S®, is the only procedure recognized by the American National Standards Institute (ANSI). If the Manual J load calculation is done then the next necessary heating and cooling. ACCA’S Residential Design Manuals Load Calculation ACCA Manual J ACCA Manual D ACCA Manual B Test, Adjust, and Balance ACCA Manual S Equipment Selection DuctDesign. Acca manual s download. Reply |
DOCUMENTS / MANUALSView All
FEATURES
- Simple – Maintenance-free, multi-use, disposable cartridge PAKs and intuitive touchscreen menus are easy to use
- Flexible – Customized cartridge configurations and a broad test menu, including pH, pO2, pCO2, hematocrit, electrolytes and metabolites, meet the needs of any location and any testing capacity, cost-effectively.
- iQM –IL's proprietary Intelligent Quality Management provides continuous, real-time quality control for the most accurate results, every time.
- Total connectivity – GEMweb software allows information management and real-time communication throughout the hospital.
SPECIFICATIONS
Height | 17.5 in |
Length | 11.8 in |
Weight | 31.2 lbs |
Width | 13 in |
Additional Specifications
Sample Volume
-135µL BG*, Hct cartridges
-135µL BG, Lytes,** Hct cartridges
-145µL BG, Lytes, Glu, Lac, Hct cartridges
-150µL BG, Lytes, Glu, Lac, Hct cartridges
*BG = pH, pCO2, pO2
**Lytes = Na+, K+ and Ca++
Time to Results: 85 seconds from sample introduction
Gem Premier 4000 User Manual Pdf Online
NEWSView All
Gem Premier 4000 Analyzer
Device AlertGem 4000 Premier
Instrumentation Laboratory GmbH has issued an information that the package inserts for certain product lots of GEM Check Coag Whole Blood Controls contain incorrect data. Instrumentation Laboratory—GEM Check Coag Whole Blood Controls: Package Insert May Contain Incorrect Acceptable Performance Range See attached PDF under Manuals & Resource ..